Re: CPSC warns consumers to stop using male-to-male extension cords sold on Amazon

#131
post #86

All these cable stories always make me wonder: Is it possible to design a safe gender-less power plug? By that I mean one that has no male and female end but two symmetrical ones. That would not only be safer but also more convenient as there would only be one type of such cable, instead of three: (female-male, female-female, male-male).

It's called USB-C

Re: CPSC warns consumers to stop using male-to-male extension cords sold on Amazon

#132
post #43

How can folks not see that using such contraption is obviously a shitty idea? That’s why we need to completely overhaul the teaching of physics in middle and high school. Every citizen should have at least a basic understanding of basic physical concepts that allow then to understand why this kind of thing is a bad idea

So, I have a very good understanding of basic physics. I have a very good ability to critically think. I am, what I would consider, educated and intelligent. And there was a time in my life when I googled "double male cord" because my snow-blower has a female plug for the electric start that is supposed to go to a converter box specifically sold by the company, and I lost it and didn't want to pay $100 for a new one.…

If you plugged your double cord into the snowblower and never unplugged it, it wouldn't be that unsafe.

Re: CPSC warns consumers to stop using male-to-male extension cords sold on Amazon

#133
post #8

Back feeding seems insane. Most residential circuits are rated for 15A. A 5000 watt generator can produce over 40 amps at 120V. Seems like a good way to start an electrical fire.

There's not a big risk of overcurrent here, since the 15A breaker will trip on overcurrent even when it's being backfed. The main hazard with these suicide cables is of electrocution, both inside your house due to the exposed blades being energized, and of linemen working to restore the power.

I wonder what happens when the grid comes back up at a mismatched phase. If only mythbusters were still around. :-)

Re: CPSC warns consumers to stop using male-to-male extension cords sold on Amazon

#134

How can folks not see that using such contraption is obviously a shitty idea? That’s why we need to completely overhaul the teaching of physics in middle and high school. Every citizen should have at least a basic understanding of basic physical concepts that allow then to understand why this kind of thing is a bad idea

The fact it got taught in school is only lightly correlated to what adult will know. It's also indirect, like, math teaches you everything you need to know to calculate load or do your taxes, or home budget, yet people have problems with it coz they never had someone teach them how to apply knowledge to real problems

Re: CPSC warns consumers to stop using male-to-male extension cords sold on Amazon

#135
post #6

Earlier quoted context omitted.

What other use is there for male-to-male cables?

The classic "I started with the wrong end when I put up the Christmas lights"?

Then fix it. It's much better to take the L and fix your lights than burn your f*ing house down.

Re: CPSC warns consumers to stop using male-to-male extension cords sold on Amazon

#136
post #111

Earlier quoted context omitted.

There are reasonably priced (under $100, though not under $3 like a common receptacle) male power inlets. https://www.homedepot.com/p/Reliance-Controls-30-Amp-Power-I... is the first one I found on Google (4-wire for 240V center-tapped), but there are many, including a 120V version: https://www.amazon.com/Leviton-5278-CWP-Straight-Flanged-Rec... Even these, if hardwired to the building's service, represent some risk,…

Unless it is installed properly, that is just as dangerous as the cord in the article, as long as you remember the "plug generator in last" rule. In particular, both can kill hapless power company employees by unexpectedly backfeeding into downed parts of the grid, and they have similar carbon monoxide/fire hazard issues. (Not that there is anything wrong with the product; I wish they were mandatory, so they'd reliab…

The actual chance of your generator backfeeding the grid is nigh nill. The issue is that all your neighbors are still connected. The moment your generator touches the grid it acts as pretty much a dead short.

Not saying it can't happen. The main one where it could is if the break is between your house and everybody else. But in the vast majority of situations you will instantly pop the dinky 15a breaker

Re: CPSC warns consumers to stop using male-to-male extension cords sold on Amazon

#137
Thought experiment: Could you make one of these wires that is safe?

I think you'd have to start with human rated GFCI... Current GFCI systems aren't human rated (ie. they might fail, and should only be used as a secondary safety feature, not the primary way to stop the user touching the electricity).

Re: CPSC warns consumers to stop using male-to-male extension cords sold on Amazon

#138

How can folks not see that using such contraption is obviously a shitty idea? That’s why we need to completely overhaul the teaching of physics in middle and high school. Every citizen should have at least a basic understanding of basic physical concepts that allow then to understand why this kind of thing is a bad idea

Electricity is like magic to most people. If you ask around you'll find that folks don't have the vaguest idea how it works. All they know is "plug it in and it turns on". These people are eating and sleeping inches from voltages that could easily kill them. Safety measures are fairly good (even with the terrible US plugs), but safety devices can only go so far. I would strongly encourage that everyone (even those wh…

Water analogues kinda assumes you somehow know hydraulics but not electrics tho.

Re: CPSC warns consumers to stop using male-to-male extension cords sold on Amazon

#139
post #62

My grandma fried a printer/laptop once accidentally doing an unintentional version of this. The printer and laptop were plugged into different circuits and there was a big enough voltage difference if fried one of them.

Likely due to neutral not being tied to a cold water pipe.

In my country (NL) it is advised against that (though it used to be common practice), since a bit of water pipe running from your house might have been replaced with a plastic one and the metal bit still sticking out into your house might not have the proper ground resistance to function as a proper earth wire.

Re: CPSC warns consumers to stop using male-to-male extension cords sold on Amazon

#140
post #102

Earlier quoted context omitted.

I mean most people know it's a terrible idea, it's just that 0.1% of a population of 330 million people is 330k people, and I don't think that 0.1% is from a failure of our education system

Why would you think that most people would just know it’s a terrible idea? After all, the vast majority of (digital) cables that people use mostly work just fine so long as they fit—leaving aside vagaries of USB-C and Thunderbolt.

> Why would you think that most people would just know it’s a terrible idea?

I dunno, statistic about deaths from electrocution?