I’m not saying this isn’t a legitimate concern but this really seems to have exploded amongst the tech community as the next obsession. I see this pop up on X every few weeks. Is the concern about this really based on actual science? Is there empirical data proving people are less productive or are damaging themselves as a result of heightened CO2 levels? And I don’t mean observational epidemiology studies.
The bottleneck might be the air in the room
131–140 of 499 posts
Re: The bottleneck might be the air in the room
#132Earlier quoted context omitted.
I'm using a bunch of IKEA's "smart home" stuff, all via Zigbee+HA, works great. Look for the Zigbee icon on the package, and the pairing for Zigbee vs their own home controller might have slightly different pairing sequence on the device, otherwise it just seems to work.
ALSTUGA does not work with Zigbee. They recently overhauled their lineup and replaced all Zigbee devices by Thread + Matter. Some of the new devices (mostly those who support TouchLink, e.g. some of the lights) have a secret pairing mode with which you can use them with Zigbee, but it's only a subset of the new products.
Uuh, seems not keeping up with social media finally backfired. That sounds horrible! So far IKEA been a great experience when it comes to HA+Zigbee stuff, and I started buying stuff relying on they'd keep just keeping up with that, really sad to hear they've changed course.
The "secret pairing mode" stuff sounds the same as currently/before though, but they only do so for a subset is new and hope they again change their mind.
Re: The bottleneck might be the air in the room
#133Don't forget too, if the CO2 is 1000 ppm, then half of the air in each breath you inhale was recently exhaled by someone else. Yes, airborne viruses are still spreading. I still wear an N95 mask whenever I'm in an indoor space with other people outside of home. IKEA now has a remarkably cheap ($35) air quality monitor that measures CO2 as well as PM: https://www.ikea.com/us/en/p/alpstuga-air-quality-sensor-sma... I d…
[flagged]
Re: The bottleneck might be the air in the room
#134I once woke up with the fam in a hotel with airco at 5500 ppm. It is then that I learned the airco does not blow fresh air (logical after thinking about it).
Re: The bottleneck might be the air in the room
#135I’m not saying this isn’t a legitimate concern but this really seems to have exploded amongst the tech community as the next obsession. I see this pop up on X every few weeks. Is the concern about this really based on actual science? Is there empirical data proving people are less productive or are damaging themselves as a result of heightened CO2 levels? And I don’t mean observational epidemiology studies.
It's peak HN meme material because 1) it (allegedly) affects your intelligence which everyone here values highly 2) you can measure it, it's a number 3) requires tech to measure it So perfect for HN, you can obsess over numbers and tech and how to measure it endlessly and overhype the significance to trick yourself into thinking you're doing something useful. You get to have your cake and eat it, no wonder everyone l…
Re: The bottleneck might be the air in the room
#136I’m not saying this isn’t a legitimate concern but this really seems to have exploded amongst the tech community as the next obsession. I see this pop up on X every few weeks. Is the concern about this really based on actual science? Is there empirical data proving people are less productive or are damaging themselves as a result of heightened CO2 levels? And I don’t mean observational epidemiology studies.
Re: The bottleneck might be the air in the room
#137Earlier quoted context omitted.
> Raising awareness is the only real solution. You'd have to raise awareness on every single person in the room and them sustain pressure to the organization in order to have proper CO2 levels in the room/organization. And then you have to align every other person on every other organization to do this as well and hope for the best. Or, you can do the right thing and have the state introduce regulations
I can just imagine the horrors and skin crawls that your last sentence has evoked in some people's minds. Not the state!! But seriously, so much care needs to be taken here. OK, well "care" at least. Employers certainly would benefit from scrubbing CO2 from the air, in terms of productivity. I'm willing to bet that with central air it would be quite easy, and even with heat and AC off, lots of places still circulate…
The place to look is existing codes for ventilation. Exempli gratia: https://dos.ny.gov/system/files/documents/2020/09/2020-mcnys... (see PDF page 46). Regulations to enforce outside air being brought into human spaces already exist.
I have been in some office buildings in United States which had CO2 monitors in each meeting room, and the ventilation would engage to control CO2 below a set level. We would entertain ourselves by exhausting our lungs onto the sensors to trigger the ventilation system.
Re: The bottleneck might be the air in the room
#138After testing a variety of AQI sensors, I ended up acquiring multiple Airthings-branded devices.
They provided the best mix of CO2/VOCs/PM sensors in a single device with a decent enough app.
There may be better options now, but I have these at both home and office.
Highly recommend doing the research and learning about the environments you’re in, especially if you have little ones at home.
Edit to add: opening windows is usually the easiest/best solution!
Re: The bottleneck might be the air in the room
#139I really wish a Apple or another major OEM would integrate CO2 monitor into watches or smartphones. Suddenly, everybody would be aware of the CO2 level in the room, get alerts, etc. and the problem will just solve itself. There are so many rooms, classrooms, movie theaters and other places with poor ventilation where you just feel dizzy, or fall asleep, not knowing it was just due to lower oxygen levels in your blood…
I think the issue is that the common tech requires sensors in an air-chamber. E.g. NDIR works by firing IR at a frequency that is absorbed by CO2. A sensor on the other side either measures the amount of IR light that got through (optical NDIR) or pressure/sound waves (photoacoustic NDIR). I guess that it's hard to use any existing sensors, because they are relatively large and probably water could easily get into th…
The question is if oxygen levels are as good an indicator as CO2 levels... I suspect not.
Re: The bottleneck might be the air in the room
#140Earlier quoted context omitted.
Apple watches already have a blood-oxygen sensor so it's covered, albeit indirectly.
I don't think that's true at all. Capnography, the measure of carbon dioxide partial pressure is wholly separate from pulseox: > Pulse oximeters have some limitations. They can only employ light at two wavelengths. Thus the devices can only distinguish between hemoglobin and oxygenated hemoglobin. When carboxyhemoglobin and methemoglobin are also present, there are two additional wavelengths required for differentiat…
Why only 2?