I feel like we have moved into the era now where if you were putting cabling in the walls for networking you should be choosing fibre now. Not necessarily because we are definitely at the stage where the home needs it, but because the off ramp is clearly happening for ethernet at 10gbit/s and its really high consumption and heat. Switching to fibre after 2.5gbit/s seems like the thing to do now and plenty of us now h…
> ethernet at 10gbit/s and its really high consumption and heat
Do you mean Ethernet cables get hot? Or just the networking equipment pushing that data.
I ask because I’ve never heard of Ethernet cables getting hot.
I feel like we have moved into the era now where if you were putting cabling in the walls for networking you should be choosing fibre now. Not necessarily because we are definitely at the stage where the home needs it, but because the off ramp is clearly happening for ethernet at 10gbit/s and its really high consumption and heat. Switching to fibre after 2.5gbit/s seems like the thing to do now and plenty of us now h…
I did just that relatively recently in a house we bought. OS2 single mode duplex throughout the house, all converging to a trunk which is available in three locations for equipment. It's basically future proof, but also has its own well, things. You can't really plug into a duplex (I wish though), you have to put a small switch to it with SFP+ or 28 or whatever the speed you want. Higher speed switches are also a tad expensive. And then, there's the big one - PoE. That's why I also ran CAT6A next to each duplex to rooms and they're more or less for APs in the house. Overall it's definitely future proof and fantastic, but also a bit expensive if you wanna engage that fiber through the house. Pulling the cable itself isn't much of a cost at all and I recommend it.
I think this is the first time one of my comments has ever gotten mentioned in a subsequent post, so that's cool :)
Glad it was helpful and not me being an idiot. That's a shame about the temp read out. I just checked my MikroTik and can see the same thing. In fact, the only SFP module reporting a temperature at all is the real fiber one, all of the DACs/converters report nothing. No voltage either.
> Regular people don't know this stuff... Regular people don't know whether to get Cat5, Cat5e, Cat6, or Cat7. So... yeah. > ...OM3/OM4/OM5? Single mode/Multi mode? LC/SC?... My answer is OM4, Multi-mode [0], LC. OM3, 4, and 5 will all work at 10gbit for any run you'd expect to make in most houses. I chose cable grade based on what was in stock at the local store. I chose connector type based on what fit into my NICs…
Go with single mode only for new installs. Biggest install cost is labour. The cable and optics are cheap now, and with the future (200Gbps+) being multiple wavelengths in parallel[1], we’ve pretty much hit the end of the road for MMF. [1] https://www.tiafotc.org/ieee-802-3-ethernet-standards-update...
This is the correct answer, always single mode. It's been the most future proof to date, people just keep figuring out how to cram more and more wavelengths into it.
I feel like we have moved into the era now where if you were putting cabling in the walls for networking you should be choosing fibre now. Not necessarily because we are definitely at the stage where the home needs it, but because the off ramp is clearly happening for ethernet at 10gbit/s and its really high consumption and heat. Switching to fibre after 2.5gbit/s seems like the thing to do now and plenty of us now h…
> ethernet at 10gbit/s and its really high consumption and heat Do you mean Ethernet cables get hot? Or just the networking equipment pushing that data. I ask because I’ve never heard of Ethernet cables getting hot.
PoE++ can get warm but you wont be doing that with fibre!
Before specifying fibre everywhere I suggest you note that a CAT 6 cable can manage 10G and PoE++. Its a lot more resilient to breakage too, especially outside the data centre.
If you really want to blow some cash there is CAT6A, which is probably not indicated unless you want cable lengths of more than say 50m.
I feel like we have moved into the era now where if you were putting cabling in the walls for networking you should be choosing fibre now. Not necessarily because we are definitely at the stage where the home needs it, but because the off ramp is clearly happening for ethernet at 10gbit/s and its really high consumption and heat. Switching to fibre after 2.5gbit/s seems like the thing to do now and plenty of us now h…
I have ten gigabits throughout most of my house, and you're right: copper is not happy pushing ten gigs. My 10 gigabit thunderbolt dongle weighs about a pound, and I think 90+% of that weight is just heatsink. If I've had it plugged in for awhile, if I accidentally touch that dongle it actually hurts because it's so hot. I cannot image that much heat is good for, well, anything. I have another Thunderbolt dongle that…
What standard of cable? When I rewired I ran Cat6a everywhere. My longest 10G run is ~70 meters and works just fine. Anytime I had a link issue it was because I did not do the best job in termination on the keystone jack.
To be clear the Cat6a is thicker than Cat6 and harder to work with. It makes termination a bit more tricky.
I have ten gigabits throughout most of my house, and you're right: copper is not happy pushing ten gigs. My 10 gigabit thunderbolt dongle weighs about a pound, and I think 90+% of that weight is just heatsink. If I've had it plugged in for awhile, if I accidentally touch that dongle it actually hurts because it's so hot. I cannot image that much heat is good for, well, anything. I have another Thunderbolt dongle that…
What standard of cable? When I rewired I ran Cat6a everywhere. My longest 10G run is ~70 meters and works just fine. Anytime I had a link issue it was because I did not do the best job in termination on the keystone jack. To be clear the Cat6a is thicker than Cat6 and harder to work with. It makes termination a bit more tricky.
I use Cat 8.
The cables themselves don't get too hot, but the dongles themselves seem to get really hot. I'm assuming that's a known issue given the size of the heatsinks on them.
If you are implementing 10 GBE at distances less than 5-7 m, I highly recommend standardizing on DAC cabling. It removes the need for these kinds of conversions that create these kinds of heat signatures.
So much this. The rule of thumb is: avoid SFP-RJ45 converters at all costs, you'll be burned by them (literally and figuratively).
They all are little snowflakes. Compatibility is hit-or-miss. They run hot. They eat more power. They're finnicky. Heck, they plain out lie about what they are (I've got some that pretend to be fibre with 3m of copper, sure).
So yeah, DAC it is for patch, fibre for anything more.
I feel like we have moved into the era now where if you were putting cabling in the walls for networking you should be choosing fibre now. Not necessarily because we are definitely at the stage where the home needs it, but because the off ramp is clearly happening for ethernet at 10gbit/s and its really high consumption and heat. Switching to fibre after 2.5gbit/s seems like the thing to do now and plenty of us now h…
Totally agree, I went to fiber years ago, and the decrease in latency makes it _feel_ so much faster than 10G copper, it is not funny. Besides, if you put in the "good stuff" them moving to 40G and beyond is not a problem later on. Like others said, just add a copper line for POE devices, but for systems... its fiber all the way.
I feel like we have moved into the era now where if you were putting cabling in the walls for networking you should be choosing fibre now. Not necessarily because we are definitely at the stage where the home needs it, but because the off ramp is clearly happening for ethernet at 10gbit/s and its really high consumption and heat. Switching to fibre after 2.5gbit/s seems like the thing to do now and plenty of us now h…
> I feel like we have moved into the era now where if you were putting cabling in the walls for networking you should be choosing fibre now.
How many consumer devices have an ((Q)SFP(+)) optical cage?
If you're in their pulling stuff anyway, sure, do some OS2, but for most people, for most devices, Cat 5e/6 is more useful, especially since you can do POE(+(+)) over it as well. 5e/6 gets you 10GbE to 55m, and 6A to 100m.