Re: AWS North Virginia data center outage – resolved

#4
I thought cooling was pretty much pre-planned in any data center, and you simply don't install more stuff than you can cool?

So did some cooling equipment fail here or was there an external reason for the overheating? Or does Amazon overbook the cooling in their data centers?

Re: AWS North Virginia data center outage – resolved

#6
post #5

Could someone explain to me why they don't build these things near oceans? Like nuclear plants that need plenty cooling capacity too Two loop cycle with heat exchanger to get rid of the heat

This is just a guess, but land near oceans is more expensive/populated, and water is comparatively cheap

Re: AWS North Virginia data center outage – resolved

#7
post #5

Could someone explain to me why they don't build these things near oceans? Like nuclear plants that need plenty cooling capacity too Two loop cycle with heat exchanger to get rid of the heat

I had a class in my masters about data centers (HPC Infrastructures). The professor was using some data centers somewhere in the middle of USA, in an area with hot weather as example. He compared that with ideal scenario (weather, power source, etc.).

In one of the slides, there were factors that influence the decision of where to build a data center, and several of the items involved finding a place with enough space and skilled people to work at this data center. He also commented sometimes there is politics involved on choosing the place for a next data center.

Re: AWS North Virginia data center outage – resolved

#8
post #5

Could someone explain to me why they don't build these things near oceans? Like nuclear plants that need plenty cooling capacity too Two loop cycle with heat exchanger to get rid of the heat

Off the top of my head: Ocean levels of salt in a water system are much more expensive to maintain (even the secondary loop).

Coastal land much more expensive. If you go to a remote coastal site, you probably won't have as good access to power.

Coastal sites usually exposed to more severe weather events.

Other fun unpredicatble things eg-Diablo Canyon nuclear facility has had issues with debris and jellyfish migration blocking their saltwater cooling intake.

https://www.nbcnews.com/news/world/diablo-canyon-nuclear-pla...

Re: AWS North Virginia data center outage – resolved

#9
post #5

Could someone explain to me why they don't build these things near oceans? Like nuclear plants that need plenty cooling capacity too Two loop cycle with heat exchanger to get rid of the heat

So Ashburn VA is a datacenter hub because the very first non-government Internet Exchange Point (IXP) anywhere in the world was there (https://en.wikipedia.org/wiki/MAE-East). Back in the 1990's something like half of all internet traffic all over the world hit MAE-East. That in turn made AWS put their first region there (us-east-1 preceded eu-west-1 by 2 years and us-west-1 by 3 years). Then because there were lots of people who knew how to build DC's- and lots of vendors who knew how to supply them- the Dulles Corridor became a major hub for lots of companies datacenters. For AWS, because us-east-1 was the first, it's by far the most gnarly and weird- and a lot of control planes for other AWS services end up relying on it. Which is why it goes down more often than other regions, and when it does go down it makes national news, unlike, say, eu-south-2 in Spain.

But NoVA is basically the same sort of economic cluster that Paul Krugman won his Nobel Prize in Economics for studying, just for datacenters, not factories.

Re: AWS North Virginia data center outage – resolved

#10
post #4

I thought cooling was pretty much pre-planned in any data center, and you simply don't install more stuff than you can cool? So did some cooling equipment fail here or was there an external reason for the overheating? Or does Amazon overbook the cooling in their data centers?

One of the data center's cooling loops broke.