The problem with Mr. Cool is that their DIY claim is because you don't cut the lineset (I believe they give you 25 ft). Any excess length you're supposed to coil up and hide, which is not ideal- plus you'll lose efficiency.
I believe they now sell other size lines and extensions. I got hung up on the excess line set idea and did a full DIY install of a non-DIY model mini-split. I bought, borrowed, and rented a lot of tools, spent a lot of time researching and learning. I really wish I went with the DIY model. Despite that lesson, I may do it again when I finish my attic space, but this time I'll add copper line brazing to the list.
Heat pumps of the 1800s are becoming the technology of the future
451–460 of 494 posts
Re: Heat pumps of the 1800s are becoming the technology of the future
#452I have wondered whether using a small windmill (on the roof) to power the compressor directly could work. This to prevent the energy loss of converting mechanical energy to electrical and electrical to mechanical again. Combining this with a heat/cold storage which is filled there is a lot of wind to be used when there is less, seems to be good idea as well.
Re: Heat pumps of the 1800s are becoming the technology of the future
#453Re: Heat pumps of the 1800s are becoming the technology of the future
#454Earlier quoted context omitted.
Not being snarky but why don't you just open the window for that? I have a CO2 detector that I believe is a reasonable proxy for stale air. When it goes above 1000 I simply open the windows. By the time I remember to close the windows the reading is almost always below 500.
On the west coasts of Canada (BC) we've had insane forest fires the past few years and you 100% want to filter the internal air when it's extremely unhealthy outside. We're talking air quality index in the 300+ range or off the charts at times [1]. Plus, we've had these heat domes were it's in the high 30+ and just gross inside, where you really want to open the windows, but you're letting in tons of pollution. Basic…
Re: Heat pumps of the 1800s are becoming the technology of the future
#455Earlier quoted context omitted.
If it's pretty cold outside, then you're throwing all of the ostensible energy savings of a heat pump out the window the minute you open it to air out the house. Following the thread of conversation, it just didn't compute to me: >>>> Heat pumps are great for climate control >>> Yeah, ducts are dead >> What if you want to recirculate air in your house through your central air filter to eliminate smells? > Just open t…
For an existing dwelling, the best solution is probably mini splits (wall mounted) combined with decentralised heat recovery ventilation as required. Ducts running in an insulated space are sources of huge energy loss.
Re: Heat pumps of the 1800s are becoming the technology of the future
#456Earlier quoted context omitted.
> But I agree, nothing is more infuriating than seeing the AC on and the outdoor air temperature being lower Won't cooler temps outside make the AC work more efficiently and get to the desired temp more quickly?
yes but it still will be a lot less efficient than a window
Re: Heat pumps of the 1800s are becoming the technology of the future
#457Earlier quoted context omitted.
It doesn't get that cold in most places in Australia does it? Heat pumps need to be scaled for the maximum heating or cooling load, whichever is greater. The optimal situation is that the heating and cooling loads are similar, but in colder parts of the U.S. the heating load is much larger than the cooling load and the case for the heat pump is not so good as a place where the need for heating and cooling are more ba…
We have a brand new Daikin VRV system in new york and are currently working on retrofitting a nat gas heating solution - heat pumps aren't a good fit for anywhere north of Atlanta: When it's really cold out (say 25F or below), the heat pump stops for around 10mins to defrost the exterior coils, which means no heat running at all in that period, and this pause happens more frequently the colder it's outside. The end r…
My limited understanding of the defrost cycle is that it’s most a problem around 0c? If it’s a colder or warmer it doesn’t get triggered as often?
Re: Heat pumps of the 1800s are becoming the technology of the future
#458Earlier quoted context omitted.
I paid real money to have my ducts removed. They cause issues installing comprehensive insulation and caused hot/cold spots on the ceiling.
Honest question: Why would one care about cold or hot spots on the ceiling? I don't spend much time up there.
[edit: add link]
[0] https://www.energyvanguard.com/blog/Flat-or-Lumpy-How-Would-...
Re: Heat pumps of the 1800s are becoming the technology of the future
#459> owners of drafty homes may need to take on the added cost of insulation when installing a heat pump Installing good insulation is also really important even if you're not using heat pumps! With bad insulation, you're wasting energy no matter what technology you're using.
Sure, but don't overlook air sealing. Drafts are caused by air getting through. Most kinds of insulation won't solve this problem.
Re: Heat pumps of the 1800s are becoming the technology of the future
#460Earlier quoted context omitted.
Less that 2% of insulation being out of place can waste something like 40% or some ridiculous amount of energy. It's quite nuts how even just a little break in insulation can have a significantly negative effect. A few years after I moved into my first home - a townhouse - I added some R-16 bats to the already existing R-12 insulation in the attic and it more than cut my heating bill in half. It was a three story nar…
Okay but that's not what I was asking. That much heat loss will affect the overall temperature.