> No, that's not true! What if the return current goes through a different wire that was used as a quick fix for some wiring problem someone ran into 50 years ago?
That is potentially quite dangerous, especially if that different wire is sitting on a different breaker.
We need a lot more electricians
481–490 of 533 posts
Re: We need a lot more electricians
#482Earlier quoted context omitted.
The bigger downside is nuisance tripping because the breaker doesn't like electrical noise emitted by some device or another in your house. I don't have any AFCIs but I've heard it's pretty common. You'd rather have one circuit go out instead of the whole house, and if all you have is the one AFCI breaker you're going to have a much harder time identifying what device(s) is the culprit.
I've mostly used them on new circuits, but have put them on a few of my older circuits too. For my small sample size, I've yet to have one nuisance trip.
Re: We need a lot more electricians
#483Earlier quoted context omitted.
> Even after the replacement was complete the electrician had to come back and redo the wiring connections because the inspector said the PVC joint at the top of the box had to be metal instead. Right. There must be a reliable metallic path to ground. This is a big problem with PVC pipe retrofits. In older houses, plumbing and conduit are metal and good grounds, and grounding to plumbing used to be permitted. Once PV…
I was in a McDonalds the other day and an ad for my former local's apprenticeship program played over the radio. So there is some advertising here. Since they're a union, the pay scale is public: https://ibew46.com/media/6924/020623_020424_residential_area... Apprentices start at $21.30. That McDonalds had a big "now hiring" sign out front, advertising $21 an hour. Hm. Not sure if the extra thirty cents would be wort…
So for instance, one of the folks I know can do residential but also spent a year in the midwest learning how to wire up windmills. I guess that paid off in the last cycle when they had to pivot back and forth on jobs.
I just hate physical labor as a job, personally, but he makes almost as good of money as I do now, but my back will last past 50.
Re: We need a lot more electricians
#484Re: We need a lot more electricians
#485Earlier quoted context omitted.
> And certain circuits I go with AFCI instead. IIRC, in the US, code now requires AFCI pretty much everywhere except when GFCI is required. And AFCI is a bit of a PITA, to the point where electricians advise me against adding anything new to existing circuits in my house (because then the local inspector would require a new AFCI breaker, apparently in other areas the inspectors are less picky and would be satisfied w…
Last time I had work done, which was about six months ago, we didn't have to use AFCI for anything other than bedrooms (and maybe others, nothing that applied to the four circuits I was having installed though). Maybe a very recent change? I agree on them being a PITA sometimes. They're somewhat prone to thinking that electric motors (e.g. fans) are trying to start a fire.
Re: We need a lot more electricians
#486Something to keep in mind is that most homes, if they haven't been constructed within the last 10 years, likely have some non-compliance with the current electrical code. For instance, I needed to install an exterior disconnect which wound up costing me more than a thousand dollars on top of the existing electrical work I needed done. The electrician also needed to replace my existing ground wires because they are su…
> likely have some non-compliance with the current electrical code. It frustrates me that every year quite a lot of people are killed due to old houses not having whole-building GFCI's. A GFCI costs only $20 and can be installed inside 10 minutes. So it seems crazy to be letting people die... Yet typically electrical regs require that if an electrician installs a GFCI, they bring the whole house up to modern standard…
Re: We need a lot more electricians
#487Earlier quoted context omitted.
Now your nit picking on one thing on the list. EVs, home heat/AC, and stoves are all substantial (depending on how much you use the stove). When looked at on a macro scale there is an impact.
> When looked at on a macro scale there is an impact. At a macro level, for the chainsaws and tools that's as if each household left a single 4W LED lightbulb turned on all the time. If that's enough to have to seriously re-think the grid we're already massively doomed. I better go and talk to the power company to get approval before I plug in another lamp at home! If you don't want someone nitpicking the equivalent…
Re: We need a lot more electricians
#488Something to keep in mind is that most homes, if they haven't been constructed within the last 10 years, likely have some non-compliance with the current electrical code. For instance, I needed to install an exterior disconnect which wound up costing me more than a thousand dollars on top of the existing electrical work I needed done. The electrician also needed to replace my existing ground wires because they are su…
> ...likely have some non-compliance with the current electrical code. When I build my own residence from scratch, I'm going for a more industrial loft aesthetic vibe where all utilities are run outside the walls where they are easily accessible to frequently modify them as I please. I want to be able to frequently update to code without making a giant, expensive mess, followed by a validation inspection from a licen…
Re: We need a lot more electricians
#489Earlier quoted context omitted.
What kind of fridge do you have that draws several hundred watts continuously? I haven’t tested my fridge, but I have a very large chest freezer that never draws more than ~35W. Surely a fridge can’t be 10x worse than that.
I seriously doubt that your freezer max draw is 35W. An Energy Star freezer can only average ~25W across the entire year. I doubt that the peak is less than 1.4x the average draw. A fridge max power draw is usually during the defrost cycle. My defrost heater measures a bit over 500W.
Re: We need a lot more electricians
#490Earlier quoted context omitted.
> Good luck finding an easy-to-install whole house GFCI in the US market. Not sure I'd want one, to be honest. There are some devices that trip GFCIs and I don't think I'd like my mains to trip that easily. I just use GFCI breakers as necessary. And certain circuits I go with AFCI instead.
> There are some devices that trip GFCIs In Germany where I lived for the past decade I have never seen a non-faulty device trip a RCB. The ones that tripped it hat the full 230V on their metal case.