The focus of buildings should be: 1. Keeping dry and bulk water out/away. 2. Being as air tight as possible.† 3. Controlling vapour. 4. Being well-insulated. * https://www.buildingscience.com/documents/insights/bsi-001-t... † Air is exchanged in a controlled fashioned: filtered for pollen and other things, and then tempered with an HRV/ERV. Buildings do not need to 'breathe': * https://www.youtube.com/watch?v=CIcrXut…
Additionally, through all insulation there is an internal temperature gradient. If the there are discontinuities it is possible to get condensation when the temperature / dew point align just wrong. This can happen in in humid climates with inadequate insulation - especially fiberglass where moisture can easily penetrate the fiberglass to reach the colder outside walls.
I agree, though. Air tightness and continuous insulation coupled with well-engineered ventilation is best.