Re: Utility poles

#121
post #116

Earlier quoted context omitted.

Sigh, thanks ;)

They’re and their are my personal bugbear. I’m right there with you. :)

The way I solved that one mostly is to always repeat the sentence back and swap they’re for “they are” in my head (same for its vs it’s).

Re: Utility poles

#122
post #112
post #31

I'm now spotting fiber optic cables on different poles :) They commonly use distinguishable splice enclosures which look like this: * https://fiber-optic-catalog.ofsoptics.com/Asset/Closure.jpg * https://thumbs.dreamstime.com/z/fiber-optic-enclosure-splice...

Your bottom picture also shows half of a snowshoe fiber slack storage location. They are used at almost every splice so the splice can be moved to the ground easily and placed into a splicing trailer. That fiber pictured is a strand and lash construction where a high strength steel wire is placed and then the fiber is basically tied to it. We have stopped using any of it in favor of ADSS fiber which means all dielect…

> a snowshoe fiber slack storage. They are used at almost every splice so the splice can be moved to the ground easily and placed into a splicing trailer.

Interesting, thanks for pointing out how it's called and what's the purpose of it. I saw it around, but had no idea what it's for :)

I noticed though, that for example Optimum fiber network is using it, while Verizon one does not.

Re: Utility poles

#123
post #41

Regarding three-phase power: The electrical outlets in your home have two power-carrying prongs. The third prong is just for safety (it connects to the ground), and should never carry power unless something is going horribly wrong. In that case, the power should hopefully prefer to reach the ground through that third wire than through your human body. Anyhow, the voltage in those two power-carrying wires is constantl…

> As several people have pointed out, this isn't quite how it works in real life.

“Isn’t quite how it works” is a gross understatement. I apologize, but while there’s some correct facts, the entire narrative you spun clearly shows you don’t have the first clue what you are talking about. I really want to be as polite as possible, but what did you expect to accomplish by posting this?

Re: Utility poles

#124
post #41

Regarding three-phase power: The electrical outlets in your home have two power-carrying prongs. The third prong is just for safety (it connects to the ground), and should never carry power unless something is going horribly wrong. In that case, the power should hopefully prefer to reach the ground through that third wire than through your human body. Anyhow, the voltage in those two power-carrying wires is constantl…

This isn't correct for most residential installations in the U.S. for most of those, they have split phase power (https://en.wikipedia.org/wiki/Split-phase_electric_power) provided by a center tap transformer. This produces a neutral and two hot wires, each 180 deg out of phase from each other. Hook either hot to a neutral, and you get 120V, hook one hot to another and you get 240V.

In some places though, (I know it's common in New York, and also in a lot of datacenters), they do something like you describe, and hook 2 phases of a 3 phase system together. Since these are only 120 deg out of phase from each other instead of 180 in the split-phase system, you get less voltage, specifically 208V.

Re: Utility poles

#125

Earlier quoted context omitted.

Do the distribution transformers have "winter" ratings like the local center tapped step down transformers that feed houses? Around here it is pretty clear that Georgia Power doesn't pay much attention to the name plate ratings, winter or otherwise, when sizing and determining the number of homes per xformer.

Distribution transformers are not usually thought of as having a winter rating. On the other hand, distributions lines definitely do. Sometimes work on lines can only be done during the winter, because the load has to be shifted to lines that can only handle the increased temporary load during the winter. There is a science and an art to sizing residential xfmrs. Generally is depends on the square footage, number of…

Thanks for the info. Day job has me using the NEC frequently, and occasionally the NESC.

But I never thought about pole xformer sizing until this house. Our 35kVA (summer) faceplate xformer services nine homes. Even though it browns, it keeps on working. They've got a lot of margin, it seems

Re: Utility poles

#126
post #21

In Australia we have a life extension program for hardwood poles which slides a steel formed sock/support down the side to stabilise it for many a year more after a hard life. We had some issues with corrosive dog wee. Tar treatment sometimes works. Also steel collars to keep possums off the top structure. In Europe there are other platforms above the transform and wire complex for bird nests. Storks, cranes all abov…

As I understand it one of the largest concerns in AU are the wildfires damaging circuits connecting the disparate grids. There was some conversation about replacing some of the network poles with fire resistant poles in order to try and avoid the high number of outages caused by fires during the dry season. I'd be interested to know how that project went, and if it was successful.

Not so much bushfires damaging electrical infrastructure as electrical infrastructure starting fires. A large portion of Victoria's worst day of bushfire was sparked by a faulty power line and the electricity distribution network (22kV and below) is responsible for a good portion of fire starts, especially those lines that utilise a single wire with an earth return (SWER). The recommendations of the Royal Commission into the Black Saturday fires in regard to the electricity network are available at http://royalcommission.vic.gov.au/Commission-Reports/Final-R... and contain a whole lot of background information. Suffice to say that the recommendation (27) of the wholesale burying of thousands of kilometres of SWER line at the cost of billions of dollars haven't gone far.

Re: Utility poles

#127
post #117

I absolutely love reading about a topic from a super enthusiastic non-expert. I want to subscribe to a weekly series called "Reasonably Intelligent Person Obsesses Over Something"

Thanks! Can I suggest that you might enjoy following my blog regularly? In addition to utility poles, I have also discussed this year: Samuel Johnson's feud with James Macpherson, a fraudulent poet; the panicked history of England in 1533 after Henry VIII's mistress got pregnant; the Slaughter electric needle injector; how plutonium is used to power medical devices; equivalents of "Joe Blow" in Turkish and Hebrew. Al…

I am all over that! Thank you for sharing.

Re: Utility poles

#128
post #24

Earlier quoted context omitted.

It may be the same thing as railway sleepers: they are treated with Creosote, which is not a very good chemical

Can confirm they use creosote....nasty nasty stuff.

Yeah, doesn't smell good when you burn it either.

Re: Utility poles

#129
post #89
post #83

Earlier quoted context omitted.

While the second half of your comment is correct: >> The electrical outlets in your home have two power-carrying prongs. >Only one of the prongs carries power. The other is attached to the earth, and is always at zero volts. Voltages are about potential differentials, so "zero volts" is relatively meaningless without context. The neutral line is required by the electric code to be connected to earth at the electric p…

> Both prongs absolutely carry power. Both carry current . But not power. Power is volts * amps, and the neutral is defined as zero volts (if you ignore the voltage drop). > you can get shocked when working on junction boxes for the neutral line Only from the voltage drop on that wire. It's not the full 120v. (Unless it's cut of course, but that's a whole different story.) > Here you use voltages as a relative measur…

High voltage transmission lines can carry power without a neutral wire because they use the earth as a neutral, but in your house you can be damn sure the neutral is carrying power. Cut off the neutral blade on your appliance if you want to check it out.

"Electric power in watts produced by an electric current I consisting of a charge of Q coulombs every t seconds passing through an electric potential (voltage) difference of V is

P = work done per unit time = VQ/t = VI

Note that V is the "electric potential difference" and it take two conductors to supply power.

Re: Utility poles

#130
post #99

Those cans are filled with transformer oil, which until relatively recently consisted mostly of polychlorinated biphenyls or PCBs. Imagine how many of those cans exist across the United States and you get a sense of how big the PCB industry used to be, and why rivers such as the Hudson in New York [1] and the Housatonic in Massachusetts [2] are polluted with olympic swimming-pool sized quantities of the durable oily…

Yes, PCBs have high thermal conductivity and low electrical conductivity. Also better thermal stability than hydrocarbons. But unfortunately, quite toxic as well. And they tend to be contaminated with dioxins, which are far more toxic. Seriously, PCB/dioxin contaminated oil sold for frying? That is insane. But then, people sometimes adulterate sugar with lead acetate :(

It's kind of astonishing how far people will go in the absence of a punitive regulatory environment. One of my favorite books in Project Gutenberg is this 1820 treatise on the adulteration of foods: http://www.gutenberg.org/ebooks/19031

Everything from copper to make pickles green, to molten lead to clarify wine.