comment
Comment #42209338
FWIW, we had to have the idle speed of our fans lowered because the usual idle of around 5k RPM was WAY too much cooling. We generally run our fans at around 2.5kRPM (barely above …
-
comment
Comment #42209292
We do not put the onus on customers to tolerate data loss. Our storage is redundant and spread through the rack so that if you lose drives or even an entire computer, your data is …
-
comment
Comment #42209260
This is how our rack works (Oxide employee). In each power shelf, there are 6 power supplies and only 5 need to be functional to run at full load. If you want even more redundancy,…
-
comment
Comment #38246360
It’s certainly possible someone did a BOM substitution and didn’t due diligence on it, but I doubt it. PCB assembly houses tend to notice components that are suddenly too big for t…
-
comment
Comment #38245733
As someone who designs circuit boards professionally, the explanation is clearly lacking. There might be a thermal issue or there might not be. There is nothing conclusive in the p…
-
comment
Comment #38025443
The NIC is a chip-down Chelsio T6 ASIC with 2x100GbE ports, one going to each Ethernet switch in the rack.
-
comment
Comment #36752575
My apologies, this was not intended to be inflammatory but the quotes out of the article and the comments were raised to point out that these kinds of baseless and biased comments …
-
comment
Comment #36745797
[flagged]
-
comment
Comment #33147067
Timing adjustment per x number of data bits has been required since DDR3 but DDR4 also has internal reference voltage calibration for DQ bits (VREF_DQ). This voltage sets threshold…
-
comment
Comment #33147001
The regulators are actually quite sophisticated and have many undocumented registers that set how things like the communications with the processor work, nonlinear control algorith…
-
comment
Comment #30675275
It also turns out that not many people have 3-phase power and can support a heat/power load of 15kW in their homes ;)