Viewing profile — andy4blaze
andy4blaze
HN member- Joined
- Tue, Nov 26, 2013, 5:55 PM UTC
- HN karma
- 196
- Public activity
- 25 items
- HN profile
- View on Hacker News ↗
About andy4blaze
Recent public activity
-
comment
Comment #38266554
Andy Klein from Backblaze here. We have done some survival analysis (kaplan-meier curves). In our case, we need to have a reasonable number of failures over the observation period …
-
comment
Comment #38264570
Andy Klein from Backblaze here. Your point is a good one in that temperature fluctuation can be an important factor. We actually sample smart stats, which contain the temperature a…
-
comment
Comment #30167366
Andy from Backblaze here: The WDC model (WUH721816ALE6L0) seems to only be available in Europe, not the US. It was 549,00 EUR last time I looked back in November. I believe the las…
-
comment
Comment #27041298
Andy for Backblaze here: I looked at that 3-4 years ago. It looks like power cycling increased failure rates, but we don't power cycle our systems very often, maybe 1-2 a year, so …
-
comment
Comment #27040738
Andy for Backblaze here: A while back we did an analysis of drive failure over time, i.e. the bathtub curve. It is probably a good idea to update that, as I believe we are seeing l…
-
comment
Comment #27040661
Andy at Backblaze here. We do look at drive model failure over time. We did a post on this topic several years ago, 2015? At the time, most drive followed the bathtub curve of fail…
-
comment
Comment #25920788
Andy from Backblaze here. Larger drives do take longer to rebuild, but to date we haven't changed the encoding algorithms we built. There are other strategies like cloning which ca…
-
comment
Comment #25919608
Andy at Backblaze here. All the drives are in data centers with temps around the 75-78 degree mark. Vibrations are kept to a minimum via the chassis design. We publish the data, in…
-
comment
Comment #25919508
Andy from Backblaze here. Actually you can download a spreadsheet with all the data from the tables. There's a link at the end of the post. Better than parsing HTML for the data.
-
comment
Comment #24203365
Andy from Backblaze here. Nice thinking about the bulk ordering and considerations for RAID. All things we have considered. We use our own Reed-Solomon encoding with a 17/3 set-up …
-
comment
Comment #24203201
Andy at Backblaze here. We've looked at this and the one "issue" is the consistency of the environments from the community data. In our DCs, the drives are kept a decent temperatur…
-
comment
Comment #24203110
The average cost per GB is about $0.02/GB or $20/TB for the drive. Electricity varies based on the data center and the negotiated or local rates, so harder to calc. I like the idea…
-
comment
Comment #24200916
Andy at Backblaze here. To put a pin in it, the three main factors for which drives we use are cost, availability and reliability. We have control over reliability as our systems a…
-
comment
Comment #23158505
Andy at Backblaze here: Good to know. We used to do this with the lifetime stats, but that got lost somewhere along the way. I'll look at getting them back. Thanks.
-
comment
Comment #23158477
Andy at Backblaze here. We use SSDs in our core servers and more recently in boot drives as they both need to speed. To store data in our case we don't need the speed so its not wo…
-
comment
Comment #21515943
Andy from Backblaze here: The capacity of the boot drives ranges from 80 to 500gb typically. They are mostly hard drives with some SSDs added recently. We are switching over to SSD…
-
comment
Comment #16968486
Andy from Backblaze here. Thanks for pointing it out. The correct range is low: 0.5% to high: 1.1%. We have updated the chart.
-
comment
Comment #12960740
In the Backblaze case, they are securely wiped clean and then recycled.
-
comment
Comment #12960698
I suppose if you had a single 32TB drive that went offline for say a week, and then once it came back online you'd have some type of pent up demand and a "slow" transfer speed. Sto…
-
comment
Comment #12960257
Website is fine, Backup service is fine. Blog is overloaded and we're working on it.
-
comment
Comment #12960248
The Backblaze Vault design mitigates that as the "raid array" is scattered across 20 different Storage Pods in twenty different racks. You'd need more than three racks to go down b…
-
comment
Comment #12678427
The Botezatu et al paper is quite good. The recommendations they make are well worth further consideration in our environment. -- Andy at Backblaze.
-
comment
Comment #12656699
Besides stock management, they help use determine the overall health of a Storage Pod or Vault. They also help find trouble with other components. For example, if a backplane or ca…
-
comment
Comment #12656241
Nice analysis.
-
comment
Comment #8356337
Andy from Backblaze here: Here's the post we did about that if you're interested: https://www.backblaze.com/blog/crowdsourcing-hard-drives/